Show simple item record

dc.contributor.authorYang, Qian
dc.contributor.authorCheung, Gary S
dc.contributor.authorShen, Ya
dc.contributor.authorHuang, Dingming
dc.contributor.authorZhou, Xuedong
dc.contributor.authorGao, Yuan
dc.date.accessioned2015-09-01T17:42:13Z
dc.date.available2015-09-01T17:42:13Z
dc.date.issued2015-07-28
dc.identifier.citationBMC Oral Health. 2015 Jul 28;15(1):87
dc.identifier.urihttp://dx.doi.org/10.1186/s12903-015-0075-x
dc.identifier.urihttp://hdl.handle.net/10724/31855
dc.description.abstractAbstract Background To investigate differences in the estimated minimum remaining dentin thickness (RDT) between periapical radiographs using the paralleling and parallax technique, after simulated removal of broken instrument from the mesiobuccal (MB) canal of maxillary first molar in virtual simulation model. The 3D measurement was taken as the standard for comparison. Methods Thirty-six maxillary first molars were scanned by micro-CT and reconstructed as 3-dimensional (3D) model. A virtual fragment of an instrument was created within the MB canal in software. Removal of the broken instrument was simulated in both the 3D and 2D dataset. Then, the models of all specimens were submitted to 2D and 3D measurements for the lowest (RDT) value in each. Differences in the values between the paralleling and parallax radiographic technique and the 3D-RDT value were analyzed with two-way Analysis of Variance. The Intra-class Correlation Coefficient (ICC) was used to assess consistency of the RDT measurements between the two periapical radiographic and techniques and 3D analysis. Results There was significant difference between RDT value obtained from the paralleling technique and 3D-RDT. There were no differences between RDT obtained from parallax (angled) technique and 3D-RDT. The ICC of RDT values between paralleling technique and 3D measurement were lower than 0.75. ICC between angled radiographs and 3D technique was close to 0.75. The optimal horizontal angle for the parallax technique was about 21°. Conclusions The virtual simulation technique can provide valuable insight into the benefit/risk analysis before removal of a broken instrument. Parallel radiographs overestimate the actual remain dentin thickness in mesiobuccal canals of maxillary first molars, whereas the parallel technique would give a closer estimate to the actual thickness at a projection angle of about 21°.
dc.titleThe remaining dentin thickness investigation of the attempt to remove broken instrument from mesiobuccal canals of maxillary first molars with virtual simulation technique
dc.typeJournal Article
dc.date.updated2015-07-29T18:44:25Z
dc.language.rfc3066en
dc.rights.holderYang et al.