Show simple item record

dc.contributor.authorWang, He
dc.date.accessioned2014-03-04T22:00:29Z
dc.date.available2014-03-04T22:00:29Z
dc.date.issued2002-08
dc.identifier.otherwang_he_200208_phd
dc.identifier.urihttp://purl.galileo.usg.edu/uga_etd/wang_he_200208_phd
dc.identifier.urihttp://hdl.handle.net/10724/29344
dc.description.abstractThe purpose of the study was to investigate the effect of the design differences between the multi-radius (M-RAD) total knee arthroplasty (TKA) and the single-radius (S-RAD) TKA systems on the functional performance for the sit-to-stand and stand-to-sit movements. Sixteen participants with unilateral posterior stabilized TKA (8 M-RAD and 8 S-RAD) were involved in the study. Three dimensional kinematic and EMG analysis of the sit-to-stand and stand-to-sit tasks were conducted. One-way ANOVA analyses were performed (á = 0.05). Compared to the S-RAD group, for the sit-to-stand movement, the M-RAD group exhibited greater movement time, trunk flexion, and a tendency for trunk flexion velocity. The M-RAD TKA limb had a tendency for a briefly distinct abduction (ABD) movement during trunk flexion and a greater adduction (ADD) displacement during knee extension as compared to the S-RAD group. Also, the M-RAD group displayed higher TKA knee flexor and extensor activations than the S-RAD group. For the stand-to-sit, the M-RAD group exhibited greater ABD displacement with the ABD peak occurring at a significantly later time in comparison to the S-RAD group. In addition, the M-RAD TKA limb demonstrated greater knee flexor and extensor activations than the S-RAD TKA limb. As expected, the S-RAD group performed differently from the M-RAD group. The S-RAD group used less effort to accomplish sit-to-stand and stand-to-sit by showing less movement time and knee extensor activation. However, the M-RAD group exhibited compensatory adaptations during the trunk flexion of the sit-to-stand. The greater knee extensor EMG revealed the fact that the M-RAD group had difficulty in performing the sit-to-stand and stand-to-sit movements. Furthermore, the S-RAD TKA knee was more stable than the M-RAD TKA knee during the sitto- stand and stand-to-sit tasks because the S-RAD TKA knee displayed less ABD/ADD displacement and knee flexor co-activation EMG. The multi radii design might account for the instability of the M-RAD TKA knee as the short radii used in the mid knee flexion could cause collateral ligaments to lose tension. In conclusion, the S-RAD TKA design has advantages to facilitate knee extension movements and maintain adequate collateral ligaments’ tension.
dc.languageA biomechanical analysis of the single-radius and multi-radius total knee arthroplasty systems for the sit-to-stand and stand-to-sit
dc.publisheruga
dc.rightspublic
dc.subjectTotal knee arthroplasty
dc.subjectsit-to-stand
dc.subjectstand-to-sit
dc.subjectKinematic,
dc.subjectElectromyography
dc.titleA biomechanical analysis of the single-radius and multi-radius total knee arthroplasty systems for the sit-to-stand and stand-to-sit
dc.typeDissertation
dc.description.degreePhD
dc.description.departmentSchool of Health and Human Performance
dc.description.majorExercise Science
dc.description.advisorKathy J. Simpson
dc.description.committeeKathy J. Simpson
dc.description.committeeTed A. Baumgartner
dc.description.committeeMichael Ferrara
dc.description.committeeOrmonde M. Mahoney
dc.description.committeeSteve Olejnik


Files in this item

FilesSizeFormatView

There are no files associated with this item.

This item appears in the following Collection(s)

Show simple item record